1. <font></font>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                  0517-86918678
                  Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                  Tel:0517-86918678
                  Fax:0517-86918679
                  Email:zhongweick@https://tgqf66666.com
                  Post Encoding:211600

                  Welding cable

                  電(dian)銲(han)機電纜.jpg
                  • 電(dian)銲機(ji)電(dian)纜(lan).jpg
                  Welding cable applies to exchange does not exceed 200 v voltage and pulse peak 400 v dc arc welding …

                  Description:

                  One, the cable's brief introduction:
                  Welding cable applies to exchange does not exceed 200 v voltage and pulse peak 400 v dc arc welding machine with the secondary side connections and electrode holder.Is suitable for electric welding machine secondary side wiring and connected to the electrode holder is special cable, ac rated voltage not over 200 v and pulsating dc 400 v peak.Structure for single core, adopt more flexible conductor composite ground is made.Outside the conducting wire core of heat-resisting polyester film insulating tape around the package, the outermost layer made of rubber insulation and sheath as a protective layer.
                  2, welding machine cable use requirements:
                  1, the cable is in low voltage (maximum voltage of 200 v) under the condition of high current work, requires some patience.
                  2, cable holder line long-term allowed working temperature should not exceed 65 ℃.
                  3, motor lead wire cable frequently mobile, twisted around and casting, soft, flexible.
                  4, in easy scraping by sharp steel components, casting, so the required cable insulation tear resistance, abrasion resistance and mechanical performance is good.
                  5, using complex environmental conditions, such as sunlight, water boiling, contact mud, oil, acid and alkali liquid, etc., requires a certain climate resistance and oil resistance, solvent resistance.
                  6, sometimes encounter heat welding, good heat deformation.
                  7, often move, outside diameter is small, light weight.Due to this kind of cable electrical demand is not high, and the use of complex environmental condition, on the structure required to satisfy a variety of complex environmental factors is inappropriate.Pay attention to improve the conditions of use when used to prevent damage from the outside world.
                  Three, welding machine cable specifications and reference data:

                  specifications

                  Cable reference data

                  Nominal cross section was

                  Wire core structure
                  The number/diameter
                  number/dia.mm

                  Nominal diameter in mm

                  The reference weight Kg/Km

                  At 20 ℃ conductor resistance is not greater than Ω/Km

                  Long-term continuous load carrying capacity are allowed

                  10

                  322/0.20

                  8.3

                  146/237

                  1.91

                  75

                  16

                  513/0.20

                  9.9

                  219/237

                  1.16

                  105

                  25

                  798/0.20

                  11.3

                  314/335

                  0.758

                  135

                  35

                  1121/0.20

                  12.5

                  419/442

                  0.536

                  170

                  50

                  1596/0.20

                  14.6

                  583/615

                  0.379

                  215

                  70

                  2220/0.20

                  16.9

                  798/839

                  0.268

                  265

                  95

                  2997/0.20

                  19.2

                  1059/1111

                  0.198

                  325

                  Four, welding machine cable applicable occasions:

                  model

                  The name of the

                  YH

                  Natural rubber sheathed welding cable

                  YHF

                  Neoprene or other synthetic rubber elastomer sheathed welding cable

                  Five, welding machine cable using features:
                  1, soft, has a good bending performance.
                  2, sheath material using natural rubber or neoprene, the mixture can be applied to different occasions.
                  3, the mixture of chloroprene rubber sheath is heat resistant, oil resistant, and don't delay burning performance.
                  4, this product is suitable for exchange does not exceed 200 v voltage and pulse peak 400 v dc arc welding machine with the secondary side connections and electric welding machine.
                  Six, the maximum working temperature of cable is 65 ℃

                  model

                  The rated voltage

                  some

                  Section 2 (mm)

                  standard

                  YH 、 YHF

                  Don't make the request

                  1

                  10-185.

                  GB5013.3-1985


                  Browse:
                  Return To The Top

                  分(fen)亯(xiang)到(dao):

                  rEmur

                        1. <font></font>