1. <font></font>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                  0517-86918678
                  Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                  Tel:0517-86918678
                  Fax:0517-86918679
                  Email:zhongweick@https://tgqf66666.com
                  Post Encoding:211600

                  Thermocouple with compensation, compensation cable wire

                  補(bu)償(chang)導線.jpg
                  • 補(bu)償導(dao)線(xian).jpg
                  Products overview: thermocouple with compensation wire, compensation cable thermal electrode is used…

                  Description:

                  Products overview:
                  Thermocouple with compensation wire, compensation cable thermal electrode is used to extend the movement of the thermocouple cold end, and display instrument connection temperature measuring system.This product USES the GB/T 4989-94 the thermocouple with compensation lead national standards (equivalent to the IEC584-3, the third part the thermocouple compensation wire, international standards), insulation layer and protective layer selects the import high quality fluorine plastic, and USES the new technology of the continuous extrusion, make the product has excellent acid, alkali, wear resistance and non-combustible delay of performance, can be immersed in oil and water medium and long term use.Using temperature - 60-205-260 ℃, belong to the contemporary international advanced level.Products are mainly applied to all kinds of temperature measurement device, has been widely used in petroleum, chemical industry, metallurgy, electric power and other departments.
                  Second, the scope of application:
                  Thermocouple with compensation wire, compensation cable is suitable for the index number is S, R, K, E, N, E, T, J of thermocouple type and temperature display instrument of electrical connections between, is widely used in electric power, metallurgy, petroleum, chemical industry and so on national defense scientific research departments such as thermal temperature automatic control, with a line to block and total shielding of the cable, can effectively prevent outside interference, improve the temperature measuring accuracy.
                  Flame retardant compensation cable (wire) is mainly used for fire to demand higher occasion.Keep the product with voltage grade, with specifications of ordinary cable all performance indicators, such as: high mechanical and physical properties, excellent electrical properties and chemical corrosion resistance, etc., and flame retardant properties, avoid the spread of caused by cable fire, reducing the huge losses of life and property.
                  Low smoke low halogen flame retardant compensation cable (wire) in addition to keep the flame retardant cable outside the general properties and electrical performance also have less smoke when burning, the characteristics of small amount of hydrogen chloride gas release and low corrosive.
                  Low smoke zero halogen flame retardant compensation cable (wire) besides can satisfy the using demand of the flame retardant cable, but also has no halogen acid gas release, smoke less, produce less corrosive gas, good flame retardant performance characteristics.
                  Fluorine plastic insulation and sheath compensation cable (wire) has excellent heat resistance, anti-corrosion, acid and alkali, chemical resistance, abrasion resistance, oil resistance, ageing resistance and combustion performance.
                  Silicone rubber sheath compensation cable (wire) with softness.
                  The Ann model compensating cable (wire) also have explosion-proof features, applicable to chemical and petrochemical environment measurement and control system of gas and dust explosion and the Ann circuit.
                  Three, thermocouple compensation wire, compensation cable main technical indicators:
                  Compensation conductor model according to the varieties of products are classified into SC, KC, KX, EX, JX, TX, NC
                  Among them: a) model is the first letter and the thermocouple index number corresponding;
                  B) the letter "X" said expanded compensation conductor type (don't);
                  C) the letter "c" type compensation wires (don't).
                  Note: type SC can be compensation conductor with R type degree thermocouple
                  Fourth, using features:
                  Cable long-term allowed working temperature of conductor: heat resistant level does not exceed 200 ℃ and 260 ℃.Regular grade up to 70 ℃, 90 ℃ and 105 ℃.
                  Five, the cable lowest environment temperature:
                  Fluorine plastic insulation and sheath compensation cable to 60 ℃ fixed;The fixed installation - 20 ℃.
                  Polyvinyl chloride (PVC) plastic insulated and sheathed compensation cable to 40 ℃ fixed;The fixed installation to 15 ℃.
                  Silicone rubber sheath cable to 60 ℃ fixed;The fixed installation - 20 ℃.
                  Six, the recommended allows bending radius:
                  Polyvinyl chloride (PVC) plastic insulated and sheathed compensation no armoured layer of the cable, cable should be not less than 10 times of cable diameter;Fluorine plastic insulation and sheath compensation no armoured layer of the cable, cable should be not less than 10 times of cable diameter;Armoured layer compensation cable, should not be less than 12 times of the cable.

                  Seven, structural characteristics and use temperature:

                  Insulating layer and sheath

                  The use of temperature

                  materials

                  symbol

                  Polyvinyl chloride (PVC)

                  V

                  - 20 ~ 100 ℃

                  Non-alkali glass

                  B

                  - 25 ~ 200 ℃

                  teflon

                  F

                  - 25 ~ 200 ℃

                  Structure schematic

                  sheath

                  Insulating layer

                  Alloy wire

                  sheath

                  shield

                  Insulating layer

                  Alloy wire


                  Eight, insulation color symbol table:

                  model

                  SC

                  KC

                  KC1

                  KX

                  EX

                  JK

                  TX

                  The anode

                  red

                  red

                  red

                  red

                  red

                  red

                  red

                  The cathode

                  green

                  blue

                  Lake blue

                  black

                  brown

                  The purple

                  white

                  Nine, type, and nomenclature table:

                  model

                  Gauge grid generation number

                  Containing righteousness

                  The auxiliary code

                  Additional code

                  SC


                  With 10 - platinum platinum-rhodium thermocouple compensation type wire

                  KX


                  With nickel chrome - nickel silicon expanded lead of the thermocouple

                  KC


                  With nickel chrome - nickel silicon thermocouple compensation type compensation conductor

                  EX


                  With nickel chromium copper nickel expanded compensation of thermocouple wire

                  JX


                  With iron - copper nickel expanded compensation of thermocouple wire

                  TX


                  With copper, copper nickel expanded compensation of thermocouple wire


                  -G


                  In general use


                  -H


                  Heat with



                  A


                  Precision level



                  B


                  Regular grade




                  -V


                  Polyvinyl chloride (PVC)




                  -F


                  teflon




                  -B


                  Glass wool





                  R


                  Multi-strand wire core (single strand wire core omitted)






                  P


                  shielding







                  0.5


                  Wire core nominal cross section was 0.5







                  1.0


                  Wire core nominal cross section was 1.0







                  1.5


                  Wire core nominal cross section was 1.5







                  2.5


                  Wire core nominal cross section was 2.5


                  Browse: