                  Electric contact remote double metal thermometer

                  5電接(jie)點(dian)遠傳(chuan)雙金屬(shu)溫度(du)計.jpg
                  • 5電(dian)接點遠傳(chuan)雙金屬溫度(du)計.jpg
                  WSSX series Electric contact remote double metal thermometer Is wound into a double sheet metal ring…

                  Description:

                  Productoverview:
                  WSSX series Electric contact remote double metal thermometer Is wound into a double sheet metal ring bent on. At the end of heating expansion, drives the pointer to rotate, the instrument will display the temperature value, and prevent environmental vibration in double metal thermometer internal filling silicone oil or double metal thermometer display separation part and a measuring part to achieve the seismic effect. Electric contact bimetallic thermometer and integrated seismic electric contact bimetallic thermometer and separate seismic electric contact bimetallic thermometer 2.
                  Two, work principle:
                  WSSX series Electric contact remote double metal thermometer Electrical contact device with mechanical electric contact.When the medium temperature changes, on the free end of the thin shaft and steering transmission mechanism to drive the movable contact and pointer rotation, indicating in the dial on the change of temperature value, and when the fixed contacts (upper and lower fixed contacts) instantaneous contact or disconnection of the relay and contactor circuit in the system, in order to achieve the purpose of automatic control and alarm.
                  Three, application:
                  WSSX series Electric contact remote double metal thermometer Is a measuring instrument used in temperature field production is not very high occasions, can be directly measured gas, steam temperature, temperature measurement at 80 degrees -500 degrees below zero within the scope of the paragraph from the design has the characteristics of waterproof, corrosion resistance, shock resistance, intuitive readings, sturdy and durable, widely used in petroleum the chemical, ships, machinery, power, textile, printing and other industrial occasions.
                  Four, main features:
                  1, the scene display temperature, convenient safe and reliable, long service life;
                  2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
                  3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
                  4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
                  5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
                  Five, technical parameters:
                  1, measurement range: -80~40 degrees, -40~80 degrees, 0~50, 100, 150, 200, 250 degrees, or specified by the user;
                  2, precision class: 1.5;
                  3, working pressure: Zui pressure 4.0Mpa;
                  4, F4 coating thickness: ~0.8mm, can also be specified by the user;
                  5, quality inspection by EDM micro flaw detection, voltage 12KV, frequency of 1.6 * 106Hz breakdown;
                  6, material: ICr18Ni9Ti; metal protection tube or specified by the user;
                  7, metal protection tube: phi 6, Phi 8, Phi 10, Phi 12;
                  8, connecting dimensions: (1) movable external thread: M27 * 2, G3/4, G1/2, or specified by the user;
                  (2): DN15, 20, flange 25, HG20593, or specified by the user;
                  9, dial od: D= Phi 80, Phi 100, Phi 150.

                  Note:
                  1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
                  2, installation, non twist instrument shell.
                  3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
                  4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
                  5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
                  6, do not use media exposure in measuring container.
                  7, the use of the process should pay attention to check in time, probably in about 6 months.


                  Seven, electrical parameters:

                  Rated power (VA)

                  Working voltage (V)

                  Allow the current (A)

                  Ten

                  220VAC

                  0.7A

                  24VDC

                  Eight, insulation resistance:

                  Rated voltage

                  DC voltage test (DC)

                  insulation resistance

                  24VDC

                  One hundred

                  Seven

                  220VAC

                  Five hundred

                  Twenty

                  Normal working conditions: air temperature -25-+55 Temperature relative humidity Less than 85 %.
                  Set point error: set point error should not exceed the basic error limit One . Five Times.
                  Switching difference: switching error should not exceed the basic error limit One . Five Times.
                  Nine, technical data sheet:

                  Model

                  The measuring range of C

                  Precision grade

                  Protection tube material

                  The specification of L (mm).

                  Mounting and fixing device

                  WSSX-400

                  -40-+80

                  0-+50

                  0-+100

                  0-+150

                  0-+200

                  0-+300

                  0-+400

                  0-+500

                  One point five

                  1Cr18Ni9Ti

                  Three hundred and four

                  Three hundred and sixteen

                  316L

                  Hastelloy C-276

                  Seventy-five

                  One hundred

                  One hundred and fifty

                  Two hundred

                  Three hundred

                  Four hundred

                  Five hundred

                  Seven hundred and fifty

                  One thousand

                  No fixed device

                  WSSX-410

                  WSSX-480

                  WSSX-401

                  Movable external thread

                  WSSX-411

                  WSSX-481

                  WSSX-402

                  The movable internal thread

                  WSSX-412

                  WSSX-482

                  WSSX-403

                  Fixed thread

                  WSSX-413

                  WSSX-483

                  WSSX-404

                  Fixed flange

                  WSSX-414

                  WSSX-484

                  WSSX-405

                  Card set screw

                  WSSX-415

                  WSSX-485

                  WSSX-406

                  Sleeve flange

                  WSSX-416

                  WSSX-486

                  Ten, the selection of encoding:

                  Serial number

                  category

                  Specifications

                  Explain

                  WSS

                  X

                  Electric contact type

                  Double metal thermometer (Zhongwei control)

                  Dial diameter

                  -3


                  Phi 60

                  -4


                  Phi 100

                  -5


                  Phi 150

                  Dial form

                  Zero


                  The axial (straight)

                  One


                  Radial (angle)

                  Two


                  135 degrees to (an obtuse type)

                  Eight


                  Universal (angle adjustable type)

                  Fixed form

                  Zero


                  No fixed device

                  One


                  Movable external thread

                  Two


                  The movable internal thread

                  Three


                  Fixed thread

                  Four


                  Fixed flange

                  Five


                  Card set screw

                  Six


                  Sleeve flange

                  Type of protection

                  -


                  Ordinary type

                  W


                  Type of protection

                  F


                  Anti-corrosion type

                  Example: universal type, dial diameter Phi 100 The temperature range. Zero ~ Four hundred C, One point five Activity level, external thread M27 * 2 Length. 450mm . WSSX-481 , Zero ~ Four hundred C, L=450 , M27 * 2 , One point fiveClass.

                  Eleven, Design selection and ordering information :
                  1, model;
                  2, precision grade;
                  3, temperature range;
                  4, fixed form;
                  5, the installation form of casing heat;
                  6, the inserted length.
                  Customer service service commitment:
                  1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
                  2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
                  3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
                  4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
                  5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


                  Browse:
                  Return To The Top

                  分亯(xiang)到:

                  zKNgv

                        1. <font></font>