                  Rosemount 3051L Flanged Installed Level Transmitter

                  儸(luo)斯矇特3051L灋蘭安裝(zhuang)液位變(bian)送(song)器(qi).jpg
                  • 儸(luo)斯矇特(te)3051L灋蘭(lan)安裝(zhuang)液(ye)位(wei)變(bian)送器(qi).jpg
                  Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

                  Description:

                  Productoverview:
                  Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
                  Two, work principle:
                  When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
                  Third, widely used:
                  For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
                  Fourth, the main features:
                  1, 5 years of continuous work without adjustment;
                  2, the temperature effect is negligible;
                  Influence of static pressure can be ignored;
                  3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
                  4, improve the self diagnosis function;
                  5, small, lightweight (standard 3.9kg);
                  6, static effects are neglected:
                  When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
                  7, excellent properties of unidirectional overvoltage:
                  The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
                  Five, technical parameters:
                  The 1. level measurement accuracy of 0.075%;
                  2. calibration range from 0.25inH2O to 8310inH2O;
                  3. flat film chip, 2-, 4-, and inch extend type diaphragm;
                  4. kinds of filling liquid optional, can meet the requirements of different applications;
                  5. clever and lightweight, easy installation and maintenance;
                  6. liquid material: 316L stainless steel, Hastelloy, tantalum.
                  Six, selection table:

                  Model

                  Product name

                  3051L

                  Flange mounted liquid level transmitter

                  Code

                  Pressure range (range /zui Small range)

                  Two

                  -250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

                  Three

                  -1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

                  Four

                  -8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

                  Code

                  output

                  A

                  4-20mA Based on a HART Digital signal protocol

                  M

                  Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

                  F

                  FF Bus

                  W

                  PROFIBUS

                  Code

                  Diaphragm size

                  Material Science

                  Extended length

                  Notes

                  G0

                  2in./DN 50

                  316L SST

                  Only the plane type

                  Extension with diameterEighty The Conduit

                  Size. Of Forty Pipe size,

                  Please consult factory.

                  H0

                  2in./DN 50

                  Hastelloy C-276

                  Only the plane type

                  J0

                  2in./DN 50

                  tantalum

                  Only the plane type

                  A0

                  3in./DN 80

                  316L SST

                  Plane type

                  A2

                  3in./DN 80

                  316L SST

                  2in./50mm

                  A4

                  3in./DN 80

                  316L SST

                  4in./100mm

                  A6

                  3in./DN 80

                  316L SST

                  6in./150mm

                  B0

                  4in./DN 100

                  316L SST

                  Plane type

                  B2

                  4in./DN 100

                  316L SST

                  2in./50mm

                  B4

                  4in./DN 100

                  316L SST

                  4in./100mm

                  B6

                  4in./DN 100

                  316L SST

                  6in./150mm

                  C0

                  3in./DN 80

                  Hastelloy C-276

                  Plane type

                  C2

                  3in./DN 80

                  Hastelloy C-276

                  2in./50mm

                  C4

                  3in./DN 80

                  Hastelloy C-276

                  4in./100mm

                  C6

                  3in./DN 80

                  Hastelloy C-276

                  6in./150mm

                  D0

                  4in./DN 100

                  Hastelloy C-276

                  Plane type

                  D2

                  4in./DN 100

                  Hastelloy C-276

                  2in./50mm

                  D4

                  4in./DN 100

                  Hastelloy C-276

                  4in./100mm

                  D6

                  4in./DN 100

                  Hastelloy C-276

                  6in./150mm

                  E0

                  3in./DN 80

                  tantalum

                  Only the plane type

                  F0

                  4in./DN 100

                  tantalum

                  Only the plane type


                  Code

                  Installation flange size

                  Rating

                  Material Science

                  Applicable to high voltage side of diaphragm size

                  M

                  2in.

                  One hundred and fifty level

                  carbon steel

                  2 in./DN50

                  A

                  3in.

                  One hundred and fifty level

                  carbon steel

                  3 in./DN80

                  B

                  4in.

                  One hundred and fifty level

                  carbon steel

                  4 in./DN100

                  N

                  2in.

                  Three hundredlevel

                  carbon steel

                  2 in./DN50

                  C

                  3in.

                  Three hundredlevel

                  carbon steel

                  3 in./DN80

                  D

                  4in.

                  Three hundredlevel

                  carbon steel

                  4 in./DN100

                  P

                  2in

                  Six hundredlevel

                  carbon steel

                  2 in./DN50

                  E

                  3in.

                  Six hundredlevel

                  carbon steel

                  3 in./DN80

                  X

                  2in.

                  One hundred and fifty level

                  SST

                  2 in./DN50

                  F

                  3in.

                  One hundred and fifty level

                  SST

                  3 in./DN80

                  G

                  4in.

                  One hundred and fifty level

                  SST

                  4 in./DN100

                  Y

                  2in.

                  Three hundredlevel

                  SST

                  2 in./DN50

                  H

                  3in.

                  Three hundredlevel

                  SST

                  3 in./DN80

                  J

                  4in.

                  Three hundredlevel

                  SST

                  4 in./DN100

                  Z

                  2in.

                  Six hundredlevel

                  SST

                  2 in./DN50

                  L

                  3in.

                  Six hundredlevel

                  SST

                  3 in./DN80

                  Q

                  DN 50

                  PN 10-40

                  carbon steel

                  2 in./DN50

                  R

                  DN 80

                  PN 40

                  carbon steel

                  3 in./DN80

                  S

                  DN 100

                  PN 40

                  carbon steel

                  4 in./DN100

                  V

                  DN 100

                  PN 10/16

                  carbon steel

                  4 in./DN100

                  K

                  DN 50

                  PN 10-40

                  SST

                  2 in./DN50

                  T

                  DN 80

                  PN 40

                  SST

                  3 in./DN80

                  U

                  DN 100

                  PN 40

                  SST

                  4 in./DN100

                  W

                  DN 50

                  PN 10/16

                  SST

                  4 in./DN100


                  Code

                  The process of oil filling -High pressure side

                  Temperature limit

                  A

                  Syltherm XLT

                  -75 to One hundred and fifty C (-102 to302 ~ F)

                  C

                  D.C.704 silicone oil

                  Zero to Two hundred and five C (32 to401 degrees F)

                  D

                  D.C.200 silicone oil

                  -45 to Two hundred and five C (-49 to401 degrees F)

                  H

                  Inert liquid

                  -45 to One hundred and seventy-five C(-49 to 347 degrees F)

                  G

                  Glycerin and water

                  -15 to Ninety-five C (5 to 203 degrees F)

                  N

                  Neobee M-200

                  -15 to Two hundred and five C (5 to 401 degrees F)

                  P

                  Propylene glycol and water

                  -15 to Ninety-five C (5 to 203 degrees F)


                  Code

                  option


                  Header

                  M (1)

                  Linear meter, 0-100% scale

                  M3 (1)

                  The special calibration table, specify the range

                  M4 (1)

                  LCD Header, 0-100%

                  M7 (1)

                  LCD First, linear, special set


                  Hazardous area certification

                  E5

                  The Canadian Standards Association (CSA) Flameproof certification

                  I5 (2)

                  Factory mutual (FM) Non flammable and safety certification

                  K5

                  Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

                  C5 (3)

                  Canada certification industry and Science ( Only Canada )

                  C6 (2)

                  I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


                  ( Requirement Zui High power supply voltage 42.4Vdc)

                  K6

                  CSA/CENELEC Flameproof and intrinsically safe certification

                  EF (4)

                  China NEPSI, GB Flameproof certification standard

                  EF (2) (4)

                  China NEPSI, GB Standard essential safety certification

                  E4

                  Japanese industrial standard (JIS) Flameproof certification

                  E7

                  The Standards Association of Australia (SAA) Flameproof certification

                  E8

                  CESI/CENELEC Flameproof certification

                  I1 (2)

                  BASEEFA The essence of security authentication

                  I7 (2)

                  The Standards Association of Australia (SAA) The essence of security authentication

                  I8 (5)

                  CESI/CENELEC The essence of security authentication

                  N1 (2)

                  BASEEFA N Type certification

                  N7

                  The Standards Association of Australia (SAA) Non flammable safety certification

                  IC (2)

                  SEV The essence of security authentication


                  Other options

                  W5

                  copper O Ring type, used for vacuum occasions (non wetted parts)

                  Q4

                  Check data sheet

                  Q8 (6)

                  Material traceability, in accordance with EN 10204 3.1B

                  L4

                  316 SST Flange and bolt joints

                  V1

                  Inverting output

                  V2

                  4-20mV test signal

                  V3

                  20-100mV test signal

                  Z1 (7)

                  4- Line, 0-20mA output

                  Z2 (7)

                  4- Line, 0-16mA output

                  Z3 (7)

                  4- Line, 0-10mA output

                  F_

                  From table flush connection options in selecting a set of code

                  Seven typical models:

                  3051L2AG0RD21AAK5M5Q4
                  3051L2AH0KD21AAM5
                  3051L3AA0FD21AB



                  Browse: