1. <font></font>

                1. Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                  0517-86918678
                  Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                  Tel:0517-86918678
                  Fax:0517-86918679
                  Email:zhongweick@https://tgqf66666.com
                  Post Encoding:211600

                  Fluorine plastic insulation and sheath high temperature resistant cable

                  氟(fu)塑料絕(jue)緣(yuan)護套(tao)耐高(gao)溫電纜.jpg
                  • 氟(fu)塑(su)料(liao)絕(jue)緣護(hu)套(tao)耐高溫電纜(lan).jpg
                  Fluorine plastic insulated and sheathed high-temperature cable has good high temperature resistance,…

                  Description:

                  An overview, cables:
                  Fluorine plastic insulated and sheathed high-temperature cable has good high temperature resistance, long-term between 40 ℃ - 200 ℃ with corrosive gases, such as the work under the harsh environment.And acid and alkali resistance, oil resistance and aging resistance and other characteristics, which can effectively ensure the connection between the thermocouple and the instrument and transmission signal.Used in petroleum, chemical, power generation, metallurgy and other industrial and mining enterprises, in the high temperature, low temperature and acid, alkali, oil, water and corrosion of the gas in the bad environment do electrical instrumentation and automation control system of signal transmission lines.
                  Second, fluorine plastic insulation and sheath use high temperature resistant cable features:
                  1, the working temperature: KFF - 200, KFP1F - 200, KFP1F22, KFP1F22-260 does not exceed 200 ℃;
                  2, rated voltage Uo/U: 450/750 v and below;
                  3, the lowest temperature: fixed installation - 60 ℃;
                  4, the fixed installation - 20 ℃;
                  5, minimum bending radius: KFF type should be.
                  Three, the main technical indicators:

                  projectTechnical indicators
                  guide
                  The body of the
                  straight
                  flow
                  electricity
                  The resistance

                  0.20.350.50.751.01.52.54.06.0
                  Don't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin platingDon't tin platingTin plating
                  Conductor typeClass AB92.39455.857.536.036.724.524.818.118.212.112.27.417.564.614.703.083.11
                  R class////39.040.026.026.719.520.013.313.77.988.214.955.093.033.39
                  Test voltageTest voltage 2500 v rated voltage 450/750 v / 1 min rated voltage up to and including 300/500 test voltage 2000 v / 1 min
                  Insulation resistanceAt 20 ℃ or higher, 500 m Ω km

                  Four, fluorine plastic insulation and sheath high-temperature cable type and name:

                  modelThe name of thenote
                  KFF-200F46 insulation and sheath high temperature resistant cableLong-term working temperature of 20 ℃
                  KFP1F-200F46 insulation and sheath blocking high temperature resistant cable
                  KFF22-200F46 insulation and sheath steel tape armoured high temperature resistant cable
                  KFP1F22-200F46 insulation and sheath steel tape armoured shield, high temperature resistant cable

                  Five, the fluorine plastic insulation and sheath high-temperature cable type:


                  projectCode nameSaid Ming
                  Series generation numberKControl cable
                  Insulation materialsFFep (F46) highest working temperature 200 ℃
                  Meltability polytetrafluoroethylene (PFA), the highest working temperature 260 ℃
                  Shielding materials/
                  P1
                  No shielding can be omitted
                  Tin plated copper wire
                  Sheath materialFFep (F46) highest working temperature 200 ℃
                  Meltability polytetrafluoroethylene (PFA), the highest working temperature 260 ℃
                  Armoring materials22
                  32
                  Steel tape armoured
                  Fine steel wire armoured
                  Conductive coating/
                  Y
                  Tin plating omission
                  Silver plated
                  Heat resistant grades200
                  260
                  The highest working temperature 200 ℃
                  The highest working temperature 260 ℃
                  specifications
                  To fill out some x conductor section (N (S)
                  N:2 3 4 5 7 8 10 12 14 16 19 24 27 30 37 44 48 52
                  S:0.2 0.35 0.5 1.75 1.0 1.5 2.5 4.0 6.0(mm2)℃
                  Conductor type
                  (in brackets)
                  A
                  B
                  R
                  Single strand conductors
                  Seven strands of stranded conductor
                  More flexible conductor

                  Six, ordering information:
                  When placing order, please indicate the type, specification, wire core section, some way, block and quantity.


                  Browse: